The range of microprocessor controlled sterilizers marketed by MET has been developed over a number of years. They comply with health and safety regulations, are CE marked and can be easily validated to process many different types of product according to the needs of EN550.
 
EO Sterilisers
Complementary Products
Complementary Services
BI incubation and report - Contact MET
Further Information

  1. EOGas™ series 3plus - free-standing and table-top sterilisers
  2. Anprolene® - table-top sterilisers

 

EO GAS™ SERIES 3-PLUS STERILISERS


Is your product small or made in batches which are uneconomic for large sterilizers?
The EOGAS™ systems will offer you a real benefit if you have small batches of product to sterilise which do not fit into the processing systems of contract sterilizers.

Do you want to minimise handling of product and transport costs?
If you want to retain control over your production, using these systems you will always know where your product is.

Do you have hospital returns which need decontaminating?
The EOGAS™ system not only offers a completely safe and reliable method of decontamination it can be use as a convenient way of testing how development products are effected by sterilisation.


Product Benefits

  • Very low gas consumption
    • Uses 1/5th the amount of EO of closest competitor
    • Cartridges and sterilisation bags match load volume rather than chamber size
  • Multi-load capacity - EO is introduced directly into the packages, allowing the operator to load new bags and unload finished bags while other are being processed
  • Easy installation - no water or vacuum source required

 

EO Sterilisers

 


EO Sterilisers

Key Features

  • 100% ethylene oxide used in processing (no CFCs)
  • Sterilises and aerates in one cabinet
  • Power outage protection
  • Process display and logging
  • Typical cycle time: 16 hours
  • Complies with personnel exposure regulations, catalytic converter available to fully scrub exhaust
  • Bag containment system allows concurrent processing of several batches
  • 3 sizes available:
    • Table-top cabinet 168 litres
    • Free-standing cabinet 280 litres
    • High capacity free-standing cabinet 922 litres
  • Easy to use

 

Load Traditional Load

 

Specifications


Technical Specifications - tabletop
 
Technical Specification - larges

Top of page

 


ANPROLENE® - TABLE TOP STERILISERS


Anprolene® AN 74iThe new Anprolene® AN 74i version is a much improved upgrade of the original AN74 model and is ideal when cost or space are limited or when load volumes do not require a large steriliser.

Product Benefits

  • Simple installation
  • Very economical to run
  • Automatic sterilisation and purge cycle
  • Improved purging of sterilization bag
  • Replacement of ventilation alarm with
  • back pressure monitor
  • Sturdy steel cabinet
  • Easy maintenance

 


SPECIFICATIONS

AN74i AN74ix
Interior dimensions (LxWxH): 19.5" x 13.75" x 12.75" 29.13" x 12.75" x 13.63"
Exterior dimensions (LxWxH): 21" x 14" x 20.5" 31.5" x 13.87" x 20"
Total weight: 46 lbs 83 lbs
Power supply: 115v +/-10%, 60Hz/150Watts 115v +/-10%, 60Hz/150Watts
Installation category: Cat. II Cat. II
Certification: Both are CE marked and CSA tested for electrical safety

 


Technical Information


All mechanical and electrical components are located within the top section of the sterilizer removing the separate ventilation box. The exhaust of the gas is via a 3/8" flexible PVC tube which can be extended to 100 feet via four 90 degree turns. The tube can be run through existing exhaust ducting or exit via a window, removing the need for extensive building works .

Pumps
The dual pump system can evacuate the sterilizer chamber at 38 litres / minute via a newly designed purge tube giving a much improved air wash.

Back Pressure Monitor
The original ventilation alarm has been replaced with a monitor to give a reading on the backpressure. A high constant reading indicates that the exhaust system may be compromised.

EO Consumption
The Anprolene systems use only 17.5 grams of EO per cycle.

Monitoring of Sterilisation
The efficacy of each sterilisation cycle can be demonstrated using biological indicators. Process indicators may also be used to control inventory and indicate whether or not the product or pack has gone through sterilisation. Both types of indicators are available from MET.

Refill Kits


Each Refill Kit includes:
  • Sterilising gas ampoules: 15, 735 or 920 cc
  • Liner bags: capacity 7L or 35L
  • Twist seal closures